##// END OF EJS Templates
Merge pull request #10952 from ipython/auto-backport-of-pr-10634...
Merge pull request #10952 from ipython/auto-backport-of-pr-10634 Backport PR #10634 on branch 5.x

File last commit:

r23696:24fe5e48
r24104:37c9ed80 merge
Show More
_get_terminal_size.py
131 lines | 4.3 KiB | text/x-python | PythonLexer
/ IPython / utils / _get_terminal_size.py
Matthias Bussonnier
Vendor shutil.get_terminal_size....
r23688 # vendored version of backports.get_terminal_size as nemesapece package are a
Matthias Bussonnier
Include MIT Licence, update to master of get_terminal_size....
r23696 # mess and break, especially on ubuntu. This file is under MIT Licence.
Matthias Bussonnier
Vendor shutil.get_terminal_size....
r23688 # See https://pypi.python.org/pypi/backports.shutil_get_terminal_size
Matthias Bussonnier
Include MIT Licence, update to master of get_terminal_size....
r23696 #
# commit: afc5714b1545a5a3aa44cfb5e078d39165bf76ab (Feb 20, 2016)
# from
# https://github.com/chrippa/backports.shutil_get_terminal_size
#
# The MIT License (MIT)
#
# Copyright (c) 2014 Christopher Rosell
#
# Permission is hereby granted, free of charge, to any person obtaining a copy
# of this software and associated documentation files (the "Software"), to deal
# in the Software without restriction, including without limitation the rights
# to use, copy, modify, merge, publish, distribute, sublicense, and/or sell
# copies of the Software, and to permit persons to whom the Software is
# furnished to do so, subject to the following conditions:
#
# The above copyright notice and this permission notice shall be included in
# all copies or substantial portions of the Software.
#
# THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR
# IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY,
# FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE
# AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER
# LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM,
# OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN
# THE SOFTWARE.
#
Matthias Bussonnier
Vendor shutil.get_terminal_size....
r23688 """This is a backport of shutil.get_terminal_size from Python 3.3.
The original implementation is in C, but here we use the ctypes and
fcntl modules to create a pure Python version of os.get_terminal_size.
"""
import os
import struct
import sys
from collections import namedtuple
__all__ = ["get_terminal_size"]
terminal_size = namedtuple("terminal_size", "columns lines")
try:
Matthias Bussonnier
Include MIT Licence, update to master of get_terminal_size....
r23696 from ctypes import windll, create_string_buffer, WinError
Matthias Bussonnier
Vendor shutil.get_terminal_size....
r23688
Matthias Bussonnier
Include MIT Licence, update to master of get_terminal_size....
r23696 _handle_ids = {
0: -10,
1: -11,
2: -12,
Matthias Bussonnier
Vendor shutil.get_terminal_size....
r23688 }
def _get_terminal_size(fd):
Matthias Bussonnier
Include MIT Licence, update to master of get_terminal_size....
r23696 handle = windll.kernel32.GetStdHandle(_handle_ids[fd])
if handle == 0:
raise OSError('handle cannot be retrieved')
if handle == -1:
raise WinError()
csbi = create_string_buffer(22)
res = windll.kernel32.GetConsoleScreenBufferInfo(handle, csbi)
if res:
res = struct.unpack("hhhhHhhhhhh", csbi.raw)
left, top, right, bottom = res[5:9]
columns = right - left + 1
lines = bottom - top + 1
return terminal_size(columns, lines)
else:
raise WinError()
Matthias Bussonnier
Vendor shutil.get_terminal_size....
r23688
except ImportError:
import fcntl
import termios
def _get_terminal_size(fd):
try:
res = fcntl.ioctl(fd, termios.TIOCGWINSZ, b"\x00" * 4)
Matthias Bussonnier
Include MIT Licence, update to master of get_terminal_size....
r23696 except IOError as e:
raise OSError(e)
lines, columns = struct.unpack("hh", res)
Matthias Bussonnier
Vendor shutil.get_terminal_size....
r23688
return terminal_size(columns, lines)
def get_terminal_size(fallback=(80, 24)):
"""Get the size of the terminal window.
For each of the two dimensions, the environment variable, COLUMNS
and LINES respectively, is checked. If the variable is defined and
the value is a positive integer, it is used.
When COLUMNS or LINES is not defined, which is the common case,
the terminal connected to sys.__stdout__ is queried
by invoking os.get_terminal_size.
If the terminal size cannot be successfully queried, either because
the system doesn't support querying, or because we are not
connected to a terminal, the value given in fallback parameter
is used. Fallback defaults to (80, 24) which is the default
size used by many terminal emulators.
The value returned is a named tuple of type os.terminal_size.
"""
# Try the environment first
try:
columns = int(os.environ["COLUMNS"])
except (KeyError, ValueError):
columns = 0
try:
lines = int(os.environ["LINES"])
except (KeyError, ValueError):
lines = 0
# Only query if necessary
if columns <= 0 or lines <= 0:
try:
size = _get_terminal_size(sys.__stdout__.fileno())
except (NameError, OSError):
size = terminal_size(*fallback)
if columns <= 0:
columns = size.columns
if lines <= 0:
lines = size.lines
return terminal_size(columns, lines)
Matthias Bussonnier
Include MIT Licence, update to master of get_terminal_size....
r23696