##// END OF EJS Templates
Tell if no automatic update possible
Tell if no automatic update possible

File last commit:

r16815:a2ad9393
r22041:892b1c49
Show More
execution.rst
64 lines | 2.3 KiB | text/x-rst | RstLexer
MinRK
msg spec 5.0
r16594 .. _execution_semantics:
Execution semantics in the IPython kernel
=========================================
The execution of use code consists of the following phases:
1. Fire the ``pre_execute`` event.
2. Fire the ``pre_run_cell`` event unless silent is True.
3. Execute the ``code`` field, see below for details.
4. If execution succeeds, expressions in ``user_expressions`` are computed.
This ensures that any error in the expressions don't affect the main code execution.
MinRK
updates per review...
r16665 5. Fire the post_execute event.
MinRK
msg spec 5.0
r16594
MinRK
updates per review...
r16665 .. seealso::
Thomas Kluyver
Some doc fixes
r16815 :doc:`/config/callbacks`
MinRK
msg spec 5.0
r16594
To understand how the ``code`` field is executed, one must know that Python
code can be compiled in one of three modes (controlled by the ``mode`` argument
to the :func:`compile` builtin):
*single*
Valid for a single interactive statement (though the source can contain
multiple lines, such as a for loop). When compiled in this mode, the
generated bytecode contains special instructions that trigger the calling of
:func:`sys.displayhook` for any expression in the block that returns a value.
This means that a single statement can actually produce multiple calls to
:func:`sys.displayhook`, if for example it contains a loop where each
iteration computes an unassigned expression would generate 10 calls::
for i in range(10):
i**2
*exec*
An arbitrary amount of source code, this is how modules are compiled.
:func:`sys.displayhook` is *never* implicitly called.
*eval*
A single expression that returns a value. :func:`sys.displayhook` is *never*
implicitly called.
The ``code`` field is split into individual blocks each of which is valid for
execution in 'single' mode, and then:
- If there is only a single block: it is executed in 'single' mode.
- If there is more than one block:
* if the last one is a single line long, run all but the last in 'exec' mode
and the very last one in 'single' mode. This makes it easy to type simple
expressions at the end to see computed values.
* if the last one is no more than two lines long, run all but the last in
'exec' mode and the very last one in 'single' mode. This makes it easy to
type simple expressions at the end to see computed values. - otherwise
(last one is also multiline), run all in 'exec' mode
* otherwise (last one is also multiline), run all in 'exec' mode as a single
unit.