##// END OF EJS Templates
chg: handle EOF reading data block...
chg: handle EOF reading data block We recently discovered a case in production that chg uses 100% CPU and is trying to read data forever: recvfrom(4, "", 1814012019, 0, NULL, NULL) = 0 Using gdb, apparently readchannel() got wrong data. It was reading in an infinite loop because rsize == 0 does not exit the loop, while the server process had ended. (gdb) bt #0 ... in recv () at /lib64/libc.so.6 #1 ... in readchannel (...) at /usr/include/bits/socket2.h:45 #2 ... in readchannel (hgc=...) at hgclient.c:129 #3 ... in handleresponse (hgc=...) at hgclient.c:255 #4 ... in hgc_runcommand (hgc=..., args=<optimized>, argsize=<optimized>) #5 ... in main (argc=...486922636, argv=..., envp=...) at chg.c:661 (gdb) frame 2 (gdb) p *hgc $1 = {sockfd = 4, pid = 381152, ctx = {ch = 108 'l', data = 0x7fb05164f010 "st):\nTraceback (most recent call last):\n" "Traceback (most recent call last):\ne", maxdatasize = 1814065152," " datasize = 1814064225}, capflags = 16131} This patch addresses the infinite loop issue by detecting continuously empty responses and abort in that case. Note that datasize can be translated to ['l', ' ', 'l', 'a']. Concatenate datasize and data, it forms part of "Traceback (most recent call last):". This may indicate a server-side channeledoutput issue. If it is a race condition, we may want to use flock to protect the channels.
Jun Wu -
r29602:4fc4b8cc default
Show More
Name Size Modified Last Commit Author
/ contrib / wix
COPYING.rtf Loading ...
README.txt Loading ...
contrib.wxs Loading ...
defines.wxi Loading ...
dist.wxs Loading ...
doc.wxs Loading ...
guids.wxi Loading ...
help.wxs Loading ...
hg.cmd Loading ...
i18n.wxs Loading ...
locale.wxs Loading ...
mercurial.wxs Loading ...
templates.wxs Loading ...

WiX installer source files
==========================

The files in this folder are used by the thg-winbuild [1] package
building architecture to create a Mercurial MSI installer. These files
are versioned within the Mercurial source tree because the WXS files
must kept up to date with distribution changes within their branch. In
other words, the default branch WXS files are expected to diverge from
the stable branch WXS files. Storing them within the same repository is
the only sane way to keep the source tree and the installer in sync.

The MSI installer builder uses only the mercurial.ini file from the
contrib/win32 folder, the contents of which have been historically used
to create an InnoSetup based installer. The rest of the files there are
ignored.

The MSI packages built by thg-winbuild require elevated (admin)
privileges to be installed due to the installation of MSVC CRT libraries
under the C:\WINDOWS\WinSxS folder. Thus the InnoSetup installers may
still be useful to some users.

To build your own MSI packages, clone the thg-winbuild [1] repository
and follow the README.txt [2] instructions closely. There are fewer
prerequisites for a WiX [3] installer than an InnoSetup installer, but
they are more specific.

Direct questions or comments to Steve Borho <steve@borho.org>

[1] http://bitbucket.org/tortoisehg/thg-winbuild
[2] http://bitbucket.org/tortoisehg/thg-winbuild/src/tip/README.txt
[3] http://wix.sourceforge.net/