##// END OF EJS Templates
typing: add type hints to mpatch implementations...
typing: add type hints to mpatch implementations Again, using `merge-pyi` to apply the stubs in cext and then manually type the private methods. The generated stub without these hints inferred very little, and the stuff it did was wrong.

File last commit:

r47090:e92ca942 default
r50494:94a79703 default
Show More
compressobj.c
256 lines | 6.6 KiB | text/x-c | CLexer
/**
* Copyright (c) 2016-present, Gregory Szorc
* All rights reserved.
*
* This software may be modified and distributed under the terms
* of the BSD license. See the LICENSE file for details.
*/
#include "python-zstandard.h"
extern PyObject* ZstdError;
PyDoc_STRVAR(ZstdCompressionObj__doc__,
"Perform compression using a standard library compatible API.\n"
);
static void ZstdCompressionObj_dealloc(ZstdCompressionObj* self) {
PyMem_Free(self->output.dst);
self->output.dst = NULL;
Py_XDECREF(self->compressor);
PyObject_Del(self);
}
static PyObject* ZstdCompressionObj_compress(ZstdCompressionObj* self, PyObject* args, PyObject* kwargs) {
static char* kwlist[] = {
"data",
NULL
};
Py_buffer source;
ZSTD_inBuffer input;
size_t zresult;
PyObject* result = NULL;
Py_ssize_t resultSize = 0;
if (self->finished) {
PyErr_SetString(ZstdError, "cannot call compress() after compressor finished");
return NULL;
}
#if PY_MAJOR_VERSION >= 3
if (!PyArg_ParseTupleAndKeywords(args, kwargs, "y*:compress",
#else
if (!PyArg_ParseTupleAndKeywords(args, kwargs, "s*:compress",
#endif
kwlist, &source)) {
return NULL;
}
if (!PyBuffer_IsContiguous(&source, 'C') || source.ndim > 1) {
PyErr_SetString(PyExc_ValueError,
"data buffer should be contiguous and have at most one dimension");
goto finally;
}
input.src = source.buf;
input.size = source.len;
input.pos = 0;
while (input.pos < (size_t)source.len) {
Py_BEGIN_ALLOW_THREADS
zresult = ZSTD_compressStream2(self->compressor->cctx, &self->output,
&input, ZSTD_e_continue);
Py_END_ALLOW_THREADS
if (ZSTD_isError(zresult)) {
PyErr_Format(ZstdError, "zstd compress error: %s", ZSTD_getErrorName(zresult));
Py_CLEAR(result);
goto finally;
}
if (self->output.pos) {
if (result) {
resultSize = PyBytes_GET_SIZE(result);
if (safe_pybytes_resize(&result, resultSize + self->output.pos)) {
Py_CLEAR(result);
goto finally;
}
memcpy(PyBytes_AS_STRING(result) + resultSize,
self->output.dst, self->output.pos);
}
else {
result = PyBytes_FromStringAndSize(self->output.dst, self->output.pos);
if (!result) {
goto finally;
}
}
self->output.pos = 0;
}
}
if (NULL == result) {
result = PyBytes_FromString("");
}
finally:
PyBuffer_Release(&source);
return result;
}
static PyObject* ZstdCompressionObj_flush(ZstdCompressionObj* self, PyObject* args, PyObject* kwargs) {
static char* kwlist[] = {
"flush_mode",
NULL
};
int flushMode = compressorobj_flush_finish;
size_t zresult;
PyObject* result = NULL;
Py_ssize_t resultSize = 0;
ZSTD_inBuffer input;
ZSTD_EndDirective zFlushMode;
if (!PyArg_ParseTupleAndKeywords(args, kwargs, "|i:flush", kwlist, &flushMode)) {
return NULL;
}
if (flushMode != compressorobj_flush_finish && flushMode != compressorobj_flush_block) {
PyErr_SetString(PyExc_ValueError, "flush mode not recognized");
return NULL;
}
if (self->finished) {
PyErr_SetString(ZstdError, "compressor object already finished");
return NULL;
}
switch (flushMode) {
case compressorobj_flush_block:
zFlushMode = ZSTD_e_flush;
break;
case compressorobj_flush_finish:
zFlushMode = ZSTD_e_end;
self->finished = 1;
break;
default:
PyErr_SetString(ZstdError, "unhandled flush mode");
return NULL;
}
assert(self->output.pos == 0);
input.src = NULL;
input.size = 0;
input.pos = 0;
while (1) {
Py_BEGIN_ALLOW_THREADS
zresult = ZSTD_compressStream2(self->compressor->cctx, &self->output,
&input, zFlushMode);
Py_END_ALLOW_THREADS
if (ZSTD_isError(zresult)) {
PyErr_Format(ZstdError, "error ending compression stream: %s",
ZSTD_getErrorName(zresult));
return NULL;
}
if (self->output.pos) {
if (result) {
resultSize = PyBytes_GET_SIZE(result);
if (safe_pybytes_resize(&result, resultSize + self->output.pos)) {
Py_XDECREF(result);
return NULL;
}
memcpy(PyBytes_AS_STRING(result) + resultSize,
self->output.dst, self->output.pos);
}
else {
result = PyBytes_FromStringAndSize(self->output.dst, self->output.pos);
if (!result) {
return NULL;
}
}
self->output.pos = 0;
}
if (!zresult) {
break;
}
}
if (result) {
return result;
}
else {
return PyBytes_FromString("");
}
}
static PyMethodDef ZstdCompressionObj_methods[] = {
{ "compress", (PyCFunction)ZstdCompressionObj_compress, METH_VARARGS | METH_KEYWORDS,
PyDoc_STR("compress data") },
{ "flush", (PyCFunction)ZstdCompressionObj_flush, METH_VARARGS | METH_KEYWORDS,
PyDoc_STR("finish compression operation") },
{ NULL, NULL }
};
PyTypeObject ZstdCompressionObjType = {
PyVarObject_HEAD_INIT(NULL, 0)
"zstd.ZstdCompressionObj", /* tp_name */
sizeof(ZstdCompressionObj), /* tp_basicsize */
0, /* tp_itemsize */
(destructor)ZstdCompressionObj_dealloc, /* tp_dealloc */
0, /* tp_print */
0, /* tp_getattr */
0, /* tp_setattr */
0, /* tp_compare */
0, /* tp_repr */
0, /* tp_as_number */
0, /* tp_as_sequence */
0, /* tp_as_mapping */
0, /* tp_hash */
0, /* tp_call */
0, /* tp_str */
0, /* tp_getattro */
0, /* tp_setattro */
0, /* tp_as_buffer */
Py_TPFLAGS_DEFAULT | Py_TPFLAGS_BASETYPE, /* tp_flags */
ZstdCompressionObj__doc__, /* tp_doc */
0, /* tp_traverse */
0, /* tp_clear */
0, /* tp_richcompare */
0, /* tp_weaklistoffset */
0, /* tp_iter */
0, /* tp_iternext */
ZstdCompressionObj_methods, /* tp_methods */
0, /* tp_members */
0, /* tp_getset */
0, /* tp_base */
0, /* tp_dict */
0, /* tp_descr_get */
0, /* tp_descr_set */
0, /* tp_dictoffset */
0, /* tp_init */
0, /* tp_alloc */
PyType_GenericNew, /* tp_new */
};
void compressobj_module_init(PyObject* module) {
Py_SET_TYPE(&ZstdCompressionObjType, &PyType_Type);
if (PyType_Ready(&ZstdCompressionObjType) < 0) {
return;
}
}